In one instance, a transporter truck of Mark IIs was returned to the factory as a gate security guard noticed a paint defect on one vehicle. 5.4 L V8 (petrol) 4-speed 5-speed 6-speed manual Dimensions 2,829 mm (111.4 in) Length 4,916 mm (193.5 in)5,053 mm (198.9 in) Width 1,864 mm (73.4 in) Height 1,444 mm (56.9 in) 1,620 kg (3,570 lb)1,740 kg (3,840 lb) Chronology. Guard Door Station Mkii Manual Transmission.Guard Door Station Mkii Manual Transmission - themesskiey Suitable for the.3 CONTENTS PAGE Manual Introduction 2 System Introduction 2 System Components 2 12 System Operation 13 Vandal Resistant Panel layout and sizes 14 Installation 15 Block Diagrams 16 Cable Size tables 17 Testing the installation 18 Telephone Connections Compatibility Chart 19 Accessories Connection Guide 20 Standard wiring diagram 21 Isolated system wiring diagram Series door panel wiring diagram 23 Video system wiring diagram Apartment station system wiring diagram 26 Art136 amplifier wiring diagram 27 Trouble Shooting Guide PAGE 1 of 29 SENTRY TECHNICAL MANUAL VER1.64 MANUAL INTRODUCTION The information is this manual is intended as an installation and commissioning guide for the Sentry system. Type a name for the guard tour and specify the pause length in minutes between each tour.NEW - Paperback 448 pages Other Ford Car Repair Manuals click here Get other. To edit the guard tour’s properties, click. Go to Settings > PTZ > Guard tours.The system has no limit on the number of apartments for which it can control although we suggest using this system on small to medium sized installation of no more than 20 apartments. Technical help is also available on during office hours or via SYSTEM INTRODUCTION The Sentry system is primarily a single entrance audio or audio/video system which is capable of being expanded to multiple entrances with additional equipment. VIDEX run free training courses for engineers who have not installed the sentry system before. Any damage caused to the equipment due to faulty installations where the information in this manual has not been followed is not the responsibility of Videx Security Ltd.The individual parts are described below. A standard video system will comprise of a door panel, control cabinet, video splitters and videophones. SYSTEM COMPONENTS A standard audio system will comprise of a door panel, control cabinet and audio telephones. A range of options are also available for the apartments including a range of telephones with varying facilities, videophones, extension sounders and strobes. There are many optional extras available for the system including full line card isolation, door monitoring and access control (coded, proximity, Bio).
Guard Door Station Mkii Manual Dimensions 2(NOT USED ON SENTRY SYSTEM) F1 Switched 0V output to switch on camera. BSY Busy signal (NOT USED ON SENTRY SYSTEM) SL Switched 0V output to switch on video PSU. D- External link to door open (0V side) LED. Art.437 or 537 Amplifier + Connector PCB Connection Function 1 Receive speech from apartment 2 Transmit speech to apartment 3 Switched +12Vdc input 4 0V (Ground) CB Button common connection 1 Push button 1 output 2 Push button 2 output 10 Push button 10 output Art.837 Amplifier connections Connection Function 2 Transmit speech to apartment ~ 13Vac input for name plate lights 3 Switched +12Vdc input 1 Receive speech from apartment 4 0V (Ground) ~ 0V input for name plate lights X Not Used P2 Push button 2 output P1 Push button 1 output C Button common connection PAGE 2 of 29 SENTRY TECHNICAL MANUAL VER1.65 Art.4837 Amplifier connection Connection Function C Buttons common connection C1 Calltone out (Not used on Sentry) P1 Push button 1 output P2 Push button 2 output S1 Common relay (Not used on Sentry) S Normally Open Relay (Not used) RL 0V relay trigger (Not used on Sentry) - 0V Ground 1 Receive speech from apartment + Switched +12Vdc input 2 Transmit speech to apartment P3 Push button 3 output P4 Push button 4 output ART.136 AMPLIFIER (Software version or later) Art.4832 Amplifier connection Connection Function I Camera power input (14-20Vdc) F1 Camera 0V M/V2 Video Screen or Video sync+ V/V1 Video centre core or Video sync- C Buttons common connection C1 Calltone out (Not used on Sentry) P1 Push button 1 output S1 Common relay (Not used on Sentry S Normally Open Relay (Not used) RL 0V relay trigger (Not used on Sentry) - 0V Ground 1 Receive speech from apartment + Switched +12Vdc input 2 Transmit speech to apartment P3 Push button 3 output 680R Connection Function 1 Receive speech from apartment 2 Transmit speech to apartment + (3) +12Vdc input (Amplifier connection 3 on the Sentry PCB) - (4) 0V (Ground) (Amplifier connection 4 on the Sentry PCB) 5 Link to terminal when used on Sentry system T Electronic call tone output to common side of call buttons (NOT USED ON SENTRY SYSTEM) - Link to terminal 5 when used on Sentry system PTE push to exit button to trigger door release relay (NOT USED ON SENTRY SYSTEM) C Common connection of dry contact relay (NOT USED ON SENTRY SYSTEM) NC Normally closed connection of dry contact relay (NOT USED ON SENTRY SYSTEM) NO Normally open connection of dry contact relay (NOT USED ON SENTRY SYSTEM) D+ External link to door open (+12V side) LED. Downloading microsoft outlook for macCN1 SENTRY PCB 1 CN3 CONNECTIONS CON Terminal Function CN Vdc Input power GND 0V (Ground) NO Normally open relay CO Common relay NC Normally closed relay CB Call button common 4 0V to amplifier 3 Switched +12 to amp 1 Transmit speech to amp 2 Receive speech from amp CN2 3 Call tone line protection fuse 315mA Call in progress LED JP3 Timer jumpers for call time, speech time and relay time CN2 ENG-LO Engaged signal ENG-LA Busy lamp connection FIREMAN Fireman switch input SWITCH Triggers relay for set time TRADE Trade button input BUTTON TIME Time clock input CLOCK CN V out to telephones 7 0V to telephones 4 Call tone output 2 Transmit speech to phone 1 Receive speech from phone 5 Lock release trigger The Sentry PCB includes three jumpers to select calling time, speech time and door open time:- JP3 LINK FITTED LINK REMOVED CALL TONE LENGTH L1 15 Seconds (3 rings) 25 Seconds (6 Rings) SPEAK TIME L2 30 Seconds 90 Seconds LOCK OPEN TIME L3 5 Seconds 10 Seconds POWER SUPPLY A control cabinet for an audio system will contain a 13.8Vdc PSU with battery back up facility. The three primary components are the Sentry control PCB, power supply unit and time clock. H L Position H High volume reassurance tones Position L Low Volume reassurance tones No Jumper No reassurance tones This jumper will not adjust the reassurance tone on the Sentry system Adjustment for speech volume level at the door station Adjustment for speech volume at the apartment Please see block diagram on page 16 for cable requirements PAGE 3 of 29 SENTRY TECHNICAL MANUAL VER1.66 CONTROL CABINET The control cabinet consists of three primary components plus optional extra components such as line card isolation, door monitoring etc. Speech volume adjustments are carried out at the door panel using a small trimmer driver. This power supply only has an output when either a 0V is applied to C or when a voltage is applied to +C. 893N 20Vdc 800mA continuous 1A surge PSU. PAGE 4 of 29 SENTRY TECHNICAL MANUAL VER1.67 Art. This additional power supply is described below and is used to power the videophones and the camera. Video control cabinets will have an additional PSU rated at 20Vdc 1 Amp surge or 800mA continuous. (Care should be taken to calculate the current consumption of the lock release as it may be necessary to upgrade this power supply to either a 2 Amp or even a 3 Amp). Connection Function + 12Vac or dc voltage input - 0V TR Not used with Sentry system C Common connection on relay NO Normally open connection on relay NC Normally closed connection on relay For more information see time clock instruction sheet OPTIONAL ISOLATION PCB An isolation card will prevent a fault in a single apartment affecting the rest of the system. This will then energise the lock relay on the Sentry PCB. When used with the Sentry control system the relay is used to short the time clock inputs on the sentry PCB which will in turn enable the trade button input to accept a short from a trade button. The output is a dry contact relay. This time clock operates from a 12Vac or dc power supply. Connection Function 230V~ 0 Mains voltage input + Switched 20Vdc output (Triggered by C or +C) - 0V -C 0V trigger input (From 4V to 0V) +C + volts trigger input (From 8V up to 30V) D+ +20Vdc output via diode Art.701 BST/GMT digital time clock. ![]()
0 Comments
Leave a Reply. |
AuthorJulie ArchivesCategories |